Haimen Huahai Marine Safety Equipment Co., Ltd.
0513-82198260
2736136050@qq.com

Portable carbon dioxide fire extinguisher

2023-08-22   Haimen Huahai Maritime Safety Equipment Co., Ltd.

Carbon dioxide fire extinguishing agentis an inert gas,Leave no trace after extinguishing the fire,Strong insulation performance,Non-conductive,don't burn,non-combustible,Easy to manufacture,Easy to liquefy.portableThe carbon dioxide fire extinguisher is mainly used to save valuable equipment,booksarchives, instrumentation,600below voltschargedelectrical equipment andGeneral flammable liquid fires.2Carbon dioxide has a higher density,Has the effect of cooling and isolating air,When extinguishing a fire, carbon dioxide gas can remove air andsurrounded by burningBurning objects on the surface or distributed in a relatively closed space, reducing the oxygen concentration around the combustibles or in the protective space, resulting in suffocation and fire extinguishing. When carbon dioxide is ejected from the storage container, it will quickly vaporize from liquid to gas. absorb part of the heat from the surroundingfastcooling effect.

The portable carbon dioxide fire extinguisher produced by our company has specifications5kg,7kgIt is made of seamless steel cylinder material, not afraid of pressure, not afraid of squeezing, the body color is bright, rust-proof, pressure-resistant and corrosion-resistant.

makeusemethod

Step 1: Lift the fire extinguisher, remove the lead seal, and pull out the safety pin

Step 2: Hold the hose with one hand and press down on the handle with the other hand

Step 3: Stand in the upwind direction, 3-5 meters away from the fire source, and shoot at the root of the fire source

Precautions

1.When used outdoors, it should be sprayed in the upwind direction;

2.When using in a narrow indoor space, the operator should leave quickly after extinguishing the fire to prevent suffocation;

3.When using, try to prevent the skin from directly contacting the spray barrel and spray pipe to cause frostbite;

4.When fighting an electrical fire, if the voltage exceeds600volts, remember to cut off the power first and then put out the fire;

5.fire extinguisherIt should be avoided to be installed in damp and severely corrosive places;

6.Once the fire extinguisher is turned on, it must be refilled, and the type of fire extinguishing agent must not be changed after refilling. (Refill, on request)

7.per use or expiration5after every year2Year,It should be sent to the maintenance unit for hydrostatic test and other maintenance

Refilling requirements, this product needs to be refilled in the following situations

1.expired

2. After it has been turned on